BARE SINGLE‑MODE OPTICAL FIBER SERIES
G.652.D BARE SINGLE‑MODE OPTICAL FIBER
PRODUCT DESCRIPTION
WAVEBAND‑EXPANDED NON‑DISPERSION‑SHIFTED SINGLE‑MODE BARE OPTICAL FIBER. COMPLIES WITH ITU‑T G.652.D AND IEC B1.3 SPECIFICATIONS. PROVIDES RELIABLE FULL‑BAND TRANSMISSION FOR DWDM AND CWDM SYSTEMS, SUITABLE FOR VARIOUS TYPES OF OPTICAL CABLE STRUCTURES.
STANDARDS
MEETS OR EXCEEDS ITU‑T G.652.D AND IEC 60793‑2‑50 TYPE B1.3 OPTICAL FIBRE SPECIFICATION.
FEATURES
- 1260‑1625NM FULL‑BAND TRANSMISSION CAPABILITY
- SUPERIOR OPTICAL PERFORMANCE FOR DWDM / CWDM TRANSMISSION SYSTEM
- LOW PMD FOR HIGH‑BIT‑RATE LONG‑DISTANCE DATA TRANSMISSION
- HIGH MECHANICAL FATIGUE RESISTANCE FOR LONG‑TERM SERVICE LIFE
- STANDARD SINGLE‑MODE PERFORMANCE FOR METRO AND LONG‑HAUL NETWORK
APPLICATION
- ALL CABLE CONSTRUCTIONS INCLUDING RIBBON, LOOSE‑TUBE, CENTRAL‑TUBE DESIGNS
- METRO AREA & LONG‑HAUL TELECOMMUNICATION TRANSMISSION NETWORKS
- DWDM / CWDM HIGH‑SPEED OPTICAL TRANSMISSION PROJECTS
SPECIFICATIONS
| DIMENSIONAL SPECIFICATIONS | SPECIFICATION | |
|---|---|---|
| CLADDING DIAMETER | 125.0±0.7 UM | |
| CLADDING NON‑CIRCULARITY | ≤1% | |
| COATING DIAMETER | 245±10 UM | |
| COATING‑CLADDING CONCENTRICITY | ≤12 UM | |
| COATING NON‑CIRCULARITY | ≤6 % | |
| CORE‑CLAD CONCENTRICITY | ≤0.6 UM | |
| FIBER CURL (RADIUS) | ≥4 M | |
| DELIVERY LENGTH | 2.1‑50.4( KM/REEL) | |
| OPTICAL SPECIFICATIONS | SPECIFICATION | |
| MODE‑FIELD DIAMETER (MFD) | @1310NM | 9.2±0.4 UM |
| @1550NM | 10.4±0.8 UM | |
| ATTENUATION | @1310NM | ≤0.34 DB / KM |
| @1383NM | ≤0.34 DB / KM | |
| @1550NM | ≤0.20 DB / KM | |
| @1625NM | ≤0.24 DB / KM | |
| ATTENUATION VS WAVELENGTH | 1285‑1330NM REF λ@1310NM | ≤0.04 DB/KM |
| 1525‑1575NM REF λ@1550NM | ≤0.03 DB/KM | |
| POINT DISCONTINUITY | @1310NM | ≤0.05 DB |
| @1550NM | ≤0.05 DB | |
| POLARIZATION MODE DISPERSION (PMD) | MAX INDIVIDUAL FIBER PMD | ≤0.2 PS/√KM |
| PMD LINK DESIGN VALUE(M=20,Q=0.01%) | ≤0.1 PS/√KM | |
| TYPICAL VALUE | 0.04 PS/√KM | |
| ZERO DISPERSION WAVELENGTH λ0 | 1312±12 NM | |
| ZERO DISPERSION SLOPE S0 | ≤0.092 PS/(NM²·KM) | |
| DISPERSION | @1550NM | ≤18 PS/(NM·KM) |
| @1625NM | ≤22 PS/(NM·KM) | |
| CABLE CUTOFF WAVELENGTH λCC | ≤1260 NM | |
| MECHANICAL SPECIFICATIONS | SPECIFICATION | |
| PROOF TEST | ≥9.0N, ≥1.0%, ≥100KPSI | |
| DYNAMIC STRESS CORROSION SUSCEPTIBILITY Nd | ≥20 | |
| AVERAGE | 1.5 N | |
| PEAK | 1.3‑8.9 N | |
| MACROBEND LOSS | 1 TURN Φ30MM @1550NM | ≤0.75 DB |
| 10 TURNS Φ30MM @1550NM | ≤0.25 DB | |
| ENVIRONMENTAL SPECIFICATIONS | SPECIFICATION | |
| TEMPERATURE DEPENDENCE(-60℃TO 85℃,@1310NM&1550NM&1625NM) | ≤0.05 DB / KM | |
| WATER IMMERSION (23±2℃,30 DAYS) | ≤0.05 DB / KM | |
| DRY HEAT SOAK (85±2℃,30 DAYS) | ≤0.05 DB / KM | |
| DAMP HEAT (85±2℃,85%RH,30 DAYS) | ≤0.05 DB / KM | |
G.657.A1 BARE SINGLE‑MODE OPTICAL FIBER
PRODUCT DESCRIPTION
BEND‑INSENSITIVE SINGLE‑MODE BARE OPTICAL FIBER. COMPLIES WITH ITU‑T G.657.A1 AND IEC B6.A1 STANDARDS. FULLY COMPATIBLE WITH G.652 SERIES FIBER, OPTIMIZED FOR FTTH FTTX ACCESS NETWORK WITH 10MM MINIMUM BENDING RADIUS.
STANDARDS
MEETS OR EXCEEDS ITU‑T G.657.A1 AND IEC 60793‑2‑50 TYPE B6.A1 OPTICAL FIBRE SPECIFICATION.
FEATURES
- SUPERIOR BEND‑INSENSITIVE PERFORMANCE, MIN BENDING RADIUS 10MM
- FULLY COMPATIBLE WITH G.652 SINGLE‑MODE FIBER
- FULL‑BAND 1260‑1626NM TRANSMISSION CAPABILITY
- LOW PMD FOR HIGH‑BIT‑RATE LONG‑DISTANCE TRANSMISSION
- HIGH DYNAMIC FATIGUE PARAMETER FOR LONG‑TERM SERVICE LIFE UNDER SMALL BENDING
APPLICATION
- FTTH / FTTX ACCESS NETWORK DEPLOYMENT
- CABLES WITH SMALL BENDING‑RADIUS REQUIREMENTS
- ALL‑BAND TRANSMISSION SYSTEM 1260‑1626NM
SPECIFICATIONS
| DIMENSIONAL SPECIFICATIONS | SPECIFICATION | |
|---|---|---|
| CLADDING DIAMETER | 125.0±0.7 UM | |
| CLADDING NON‑CIRCULARITY | ≤1% | |
| COATING DIAMETER | 245±10 UM | |
| COATING‑CLADDING CONCENTRICITY | ≤12 UM | |
| COATING NON‑CIRCULARITY | ≤6 % | |
| CORE‑CLAD CONCENTRICITY | ≤0.5 UM | |
| FIBER CURL (RADIUS) | ≥4 M | |
| DELIVERY LENGTH | 2.05‑50.4( KM/REEL) | |
| OPTICAL SPECIFICATIONS | SPECIFICATION | |
| MODE‑FIELD DIAMETER (MFD) | @1310NM | 8.6±0.4 UM |
| @1550NM | 9.7±0.6 UM | |
| ATTENUATION | @1310NM | ≤0.35 DB / KM |
| @1383NM | ≤0.35 DB / KM | |
| @1550NM | ≤0.21 DB / KM | |
| @1625NM | ≤0.23 DB / KM | |
| ATTENUATION VS WAVELENGTH | 1285‑1330NM REF λ@1310NM | ≤0.04 DB/KM |
| 1525‑1575NM REF λ@1550NM | ≤0.03 DB/KM | |
| POINT DISCONTINUITY | @1310NM | ≤0.05 DB |
| @1550NM | ≤0.05 DB | |
| POLARIZATION MODE DISPERSION (PMD) | MAX INDIVIDUAL FIBER PMD | ≤0.2 PS/√KM |
| PMD LINK DESIGN VALUE(M=20,Q=0.01%) | ≤0.1 PS/√KM | |
| TYPICAL VALUE | 0.04 PS/√KM | |
| ZERO DISPERSION WAVELENGTH λ0 | 1312±12 NM | |
| ZERO DISPERSION SLOPE S0 | ≤0.092 PS/(NM²·KM) | |
| DISPERSION | @1550NM | ≤18 PS/(NM·KM) |
| @1625NM | ≤22 PS/(NM·KM) | |
| CABLE CUTOFF WAVELENGTH λCC | ≤1260 NM | |
| MECHANICAL SPECIFICATIONS | SPECIFICATION | |
| PROOF TEST | ≥9.0N, ≥1.0%, ≥100KPSI | |
| DYNAMIC STRESS CORROSION SUSCEPTIBILITY Nd | ≥20 | |
| AVERAGE | 1.5 N | |
| PEAK | 1.3‑8.9 N | |
| MACROBEND LOSS | 1 TURN Φ20MM @1550NM&1625NM | ≤0.75 DB , ≤1.5 DB |
| 10 TURNS Φ30MM @1550NM&1625NM | ≤0.25 DB , ≤1.0 DB | |
| ENVIRONMENTAL SPECIFICATIONS | SPECIFICATION | |
| TEMPERATURE DEPENDENCE(-60℃TO 85℃,@1310NM&1550NM&1625NM) | ≤0.05 DB / KM | |
| WATER IMMERSION (23±2℃,30 DAYS) | ≤0.05 DB / KM | |
| DRY HEAT SOAK (85±2℃,30 DAYS) | ≤0.05 DB / KM | |
| DAMP HEAT (85±2℃,85%RH,30 DAYS) | ≤0.05 DB / KM | |
G.657.A2 BARE SINGLE‑MODE OPTICAL FIBER
PRODUCT DESCRIPTION
ZONBULL FIBER'S BENDING INSENSITIVE G.657.A2‑200UM SINGLE‑MODE FIBER COMPLIES WITH ITU‑T G.657.A2 AND IEC B6.A2 STANDARDS. IT ACQUIRES THE OUTSTANDING CHARACTERISTICS OF G.657.A2 WITH SMALLER SIZE, WHICH HELPS TO REDUCE THE SIZE AND WEIGHT OF OPTICAL CABLE.
STANDARDS
ZONBULL FIBER® PLUS BENDING INSENSITIVE SINGLE MODE FIBRE MEETS OR EXCEEDS THE ITU‑T RECOMMENDATION G.652.D/G.657.A1/G.657.A2/G.657.B2 INCLUDING THE IEC 60793‑2‑50 TYPE B1.3/B6.A1/B6.A2/B6.B2 OPTICAL FIBRE SPECIFICATION.
FEATURES
- EXTREME BEND‑INSENSITIVE PERFORMANCE, MINIMUM BENDING RADIUS 7.5 MM
- DRONE‑GRADE HIGH‑PROOF‑TEST BARE FIBER, ≥100 KPSI TENSILE STRENGTH
- FULL‑BAND 1260‑1626 NM TRANSMISSION PERFORMANCE
- SMALLER COATING DIAMETER TO REDUCE CABLE VOLUME AND WEIGHT
- HIGH DYNAMIC FATIGUE PARAMETER Nd≥20 FOR RELIABLE SERVICE UNDER ULTRA‑SMALL BENDING CONDITIONS
APPLICATION
- TETHERED‑DRONE FPV OPTICAL DATA‑LINK SYSTEM
- FTTH / FTTX ACCESS NETWORK DEPLOYMENT
- CABLES WITH EXTREME LOW BENDING REQUIREMENTS
- SMALL‑SIZED FIBRE CABLE AND OPTICAL COMPONENT
SPECIFICATIONS
| DIMENSIONAL SPECIFICATIONS | SPECIFICATION | |
|---|---|---|
| CLADDING DIAMETER | 125.0±0.7 UM | |
| CLADDING NON‑CIRCULARITY | ≤1% | |
| COATING DIAMETER | 245±10 UM | |
| COATING‑CLADDING CONCENTRICITY | ≤12 UM | |
| COATING NON‑CIRCULARITY | ≤6 % | |
| CORE‑CLAD CONCENTRICITY | ≤0.5 UM | |
| FIBER CURL (RADIUS) | ≥4 M | |
| DELIVERY LENGTH | 2.05‑50.4( KM/REEL) | |
| OPTICAL SPECIFICATIONS | SPECIFICATION | |
| MODE‑FIELD DIAMETER (MFD) | @1310NM | 8.6±0.4 UM |
| @1550NM | 9.7±0.6 UM | |
| ATTENUATION | @1310NM | ≤0.35 DB / KM |
| @1383NM | ≤0.35 DB / KM | |
| @1550NM | ≤0.21 DB / KM | |
| @1625NM | ≤0.23DB / KM | |
| ATTENUATION VS WAVELENGTH | 1285‑1330NM REF λ@1310NM | ≤0.04 DB/KM |
| 1525‑1575NM REF λ@1550NM | ≤0.03 DB/KM | |
| POINT DISCONTINUITY | @1310NM | ≤0.05 DB |
| @1550NM | ≤0.05 DB | |
| POLARIZATION MODE DISPERSION (PMD) | MAX INDIVIDUAL FIBER PMD | ≤0.2 PS/√KM |
| PMD LINK DESIGN VALUE(M=20,Q=0.01%) | ≤0.1 PS/√KM | |
| TYPICAL VALUE | 0.04 PS/√KM | |
| ZERO DISPERSION WAVELENGTH λ0 | 1312±12 NM | |
| ZERO DISPERSION SLOPE S0 | ≤0.092 PS/(NM²·KM) | |
| DISPERSION | @1550NM | ≤18 PS/(NM·KM) |
| @1625NM | ≤22 PS/(NM·KM) | |
| CABLE CUTOFF WAVELENGTH λCC | ≤1260 NM | |
| MECHANICAL SPECIFICATIONS | SPECIFICATION | |
| PROOF TEST | ≥9.0N, ≥1.0%, ≥100KPSI | |
| DYNAMIC STRESS CORROSION SUSCEPTIBILITY Nd | ≥20 | |
| AVERAGE | 1.5 N | |
| PEAK | 1.3‑8.9 N | |
| MACROBEND LOSS | 1 TURN Φ7.5MM @1550NM&1625NM | ≤0.75 DB , ≤1.5 DB |
| 1 TURN Φ10MM @1550NM&1625NM | ≤0.25 DB , ≤0.8 DB | |
| 10 TURNS Φ15MM @1550NM&1625NM | ≤0.10 DB , ≤0.4 DB | |
| ENVIRONMENTAL SPECIFICATIONS | SPECIFICATION | |
| TEMPERATURE DEPENDENCE(-60℃TO 85℃,@1310NM&1550NM&1625NM) | ≤0.05 DB / KM | |
| WATER IMMERSION (23±2℃,30 DAYS) | ≤0.05 DB / KM | |
| DRY HEAT SOAK (85±2℃,30 DAYS) | ≤0.05 DB / KM | |
| DAMP HEAT (85±2℃,85%RH,30 DAYS) | ≤0.05 DB / KM | |
G.657.B3 ULTRA BARE SINGLE‑MODE OPTICAL FIBER
PRODUCT DESCRIPTION
ZONBULL FIBER® ULTRA FIBRE IS DESIGNED SPECIFICALLY FOR FIBRE‑TO‑THE‑HOME (FTTH), ENTERPRISE NETWORK AND ANY OTHER APPLICATIONS WHERE ULTRA LOW BENDING‑LOSS AT SMALL BENDING RADII IS NEEDED.
STANDARDS
ZONBULL FIBER® ULTRA FIBRE'S MACROBENDING PERFORMANCE AND OPTICAL PERFORMANCE ARE SUPERIOR TO THOSE RECOMMENDED IN ITU‑T G.657.B3 AND IEC 60793‑2‑50 B6.B3. DOWN TO 5 MM BENDING RADIUS, ZONBULL FIBER® ULTRA CAN MEET THE COMPLEX INSTALLATION CONDITIONS IN MDU AND FTTH, SUCH AS WALL CORNER, STAPLING, HIGH LOAD TENSION, ETC.
FEATURES
- SUPERIOR TO STANDARD ITU‑T G.657.B3 FIBRE, BENDING RADIUS DOWN TO AS SMALL AS 5MM AND FULL COMPATIBILITY WITH ALL G.652.D FIBRES
- LOW ATTENUATION SATISFYING THE OPERATION DEMAND IN O‑E‑S‑C‑L BAND
- LOW BENDING LOSS FOR HIGHLY DEMANDING CABLE DESIGNS INCLUDING RIBBONS
- ACCURATE GEOMETRICAL PARAMETERS AND LARGE MFD WHICH INSURE LOW SPLICING LOSS AND HIGH SPLICING EFFICIENCY
- HIGH ND VALUE SATISFYING LONG SERVICE LIFE IN MINIMUM BEND RADIUS
APPLICATION
- ALL TYPES OF FIBRE PATCH CORD WITH DIFFERENT STRUCTURES
- HIGH SPEED OPTICAL ROUTES FOR FIBRE‑TO‑THE‑HOME(FTTH) NETWORKS
- CABLES WITH EXTREME LOW BENDING REQUIREMENTS
- SMALL‑SIZED OPTICAL COMPONENT
SPECIFICATIONS
| DIMENSIONAL SPECIFICATIONS | SPECIFICATION | |
|---|---|---|
| CLADDING DIAMETER | 125.0±0.7 UM | |
| CLADDING NON‑CIRCULARITY | ≤0.7 % | |
| COATING DIAMETER | 235‑245 UM | |
| COATING‑CLADDING CONCENTRICITY ERROR | ≤12.0 UM | |
| COATING NON‑CIRCULARITY | ≤6.0 % | |
| CORE‑CLADDING CONCENTRICITY ERROR | ≤0.5 UM | |
| FIBER CURL (RADIUS) | ≥4 M | |
| DELIVERY LENGTH | UP TO 25.2 KM/REEL | |
| OPTICAL SPECIFICATIONS | SPECIFICATION | |
| MODE‑FIELD DIAMETER (MFD) | @1310NM | 8.2‑9.0 UM |
| @1550NM | 9.1‑10.1 UM | |
| ATTENUATION | @1310NM | ≤0.35 DB / KM |
| @1383NM (AFTER H2‑AGING) | ≤0.35 DB / KM | |
| @1550NM | ≤0.21 DB / KM | |
| @1625NM | ≤0.23 DB / KM | |
| ATTENUATION VS WAVELENGTH | 1285‑1330NM REF λ@1310NM | ≤0.03 DB/KM |
| 1525‑1575NM REF λ@1550NM | ≤0.02 DB/KM | |
| POINT DISCONTINUITIES | @1310NM | ≤0.05 DB |
| @1550NM | ≤0.05 DB | |
| POLARIZATION MODE DISPERSION (PMD) | MAXIMUM INDIVIDUAL FIBRE | ≤0.1 PS/√KM |
| PMD LINK DESIGN VALUE(M=20,Q=0.01%) | ≤0.06 PS/√KM | |
| TYPICAL VALUE | 0.04 PS/√KM | |
| ZERO DISPERSION WAVELENGTH λ0 | 1300‑1324 NM | |
| ZERO DISPERSION SLOPE S0 | ≤0.092 PS/(NM²·KM) | |
| CABLE CUTOFF WAVELENGTH λCC | ≤1260 NM | |
| MECHANICAL SPECIFICATIONS | SPECIFICATION | |
| PROOF TEST | ≥9.0N, ≥1.0%, ≥100KPSI | |
| MACRO‑BEND INDUCED LOSS (1 TURN AROUND MANDREL) | 10MM RADIUS @1550NM | ≤0.03 DB |
| 10MM RADIUS @1625NM | ≤0.1 DB | |
| 7.5MM RADIUS @1550NM | ≤0.08 DB | |
| 7.5MM RADIUS @1625NM | ≤0.25 DB | |
| 5MM RADIUS @1550NM | ≤0.15 DB | |
| 5MM RADIUS @1625NM | ≤0.45 DB | |
| TYPICAL AVERAGE FORCE | 1.5 N | |
| PEAK FORCE | 1.3‑8.9 N | |
| DYNAMIC FATIGUE PARAMETER(ND) | ≥20 | |
| ENVIRONMENTAL CHARACTERISTICS | SPECIFICATION | |
| TEMPERATURE DEPENDENCE INDUCED ATTENUATION (-60℃ TO +85℃) | ≤0.05 DB / KM | |
| TEMPERATURE‑HUMIDITY CYCLING INDUCED ATTENUATION (-10°C TO +85°C, 98% RH) | ≤0.05 DB / KM | |
| WATERSOAK DEPENDENCE INDUCED ATTENUATION (23°C, FOR 30 DAYS) | ≤0.05 DB / KM | |
| DAMP HEAT DEPENDENCE INDUCED ATTENUATION (85°C AND 85% RH, FOR 30 DAYS) | ≤0.05 DB / KM | |
| DRY HEAT AGING (85℃, FOR 30 DAYS) | ≤0.05 DB / KM | |
TECHNICAL PARAMETERS
ALL SERIES ARE DRONE‑GRADE HIGH‑PROOF‑TEST BARE FIBER. ORDINARY FTTH‑GRADE FIBER IS NOT UTILIZED.
- PROOF‑TEST TENSILE STRENGTH: ≥100 KPSI
- DELIVERY SPOOL LENGTH: 50.4 KM / DRUM STANDARD (G.657.B3 ULTRA UP TO 25.2KM/REEL)
- COATING DIAMETER: 235‑250 μm
- CLADDING DIAMETER: 125 ± 0.7 μm
PACKING LIST
EXPORT PACKING IN NON‑FUMIGATED PLYWOOD DRUMS, 5 DRUMS PER EXPORT CARTON, STACKED ON IPPC‑MARKED WOODEN PALLETS, WRAPPED WITH STRETCH FILM FOR OCEAN FREIGHT.
| SPOOL LENGTH | DESCRIPTION | HS CODE | QUANTITY | UNIT | ROLLS | CARTONS | PALLETS | NET(KG) | GROSS(KG) | CTN SIZE(CM) | PALLET SIZE(CM) | VOL(CBM) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 60.4 KM/DRUM | G657A2 BARE FIBER | 9001100002 | 24039.2 | KM | 398 | 80 | 5 | 1695 | 2360 | 60*50*31 | 120*110*142 | 9.372 |
| 50.4 KM/DRUM | G657A2 BARE FIBER | 9001100002 | 100800 | KM | 2000 | 400 | 25 | 10200 | 10700 | 60*50*31 | 120*110*142 | 45.75 |
| TOTAL | — | — | 124839.2 | KM | 2398 | 480 | 30 | 11895 | 13060 | — | — | 55.122 |
OPTIONAL BULK‑ORDER SIZING SCHEMES
| SPOOL LENGTH | DESCRIPTION | HS CODE | TARGET QUANTITY | UNIT | ROLLS | CARTONS | PALLETS | NET(KG) | GROSS(KG) | CTN SIZE(CM) | PALLET SIZE(CM) | VOL(CBM) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 50.4 KM/DRUM | BARE OPTICAL FIBER | 9001100002 | 200000 | KM | 3969 | 794 | 50 | 20242 | 21234 | 60*50*31 | 120*110*142 | 90.50 |
| 50.4 KM/DRUM | BARE OPTICAL FIBER | 9001100002 | 500000 | KM | 9921 | 1985 | 124 | 50607 | 53077 | 60*50*31 | 120*110*142 | 226.25 |
| 50.4 KM/DRUM | BARE OPTICAL FIBER | 9001100002 | 800000 | KM | 15874 | 3175 | 199 | 80957 | 84926 | 60*50*31 | 120*110*142 | 362.00 |
| 50.4 KM/DRUM | BARE OPTICAL FIBER | 9001100002 | 1000000 | KM | 19842 | 3969 | 249 | 101194 | 106155 | 60*50*31 | 120*110*142 | 452.50 |
NOTE: THE BULK‑ORDER PACKING DATA SHOWN ABOVE IS FOR REFERENCE ESTIMATION ONLY. REAL‑ORDER PACKING SPECIFICATIONS SHALL BE NEGOTIATED AND CONFIRMED BETWEEN FACTORY AND CUSTOMER. GOODS ARE DELIVERED IN FULL‑SPOOL ONLY, ACTUAL DELIVERED KILOMETERAGE EQUALS TOTAL SPOOLS × SPOOL LENGTH, FINAL PACKING DETAILS SUBJECT TO FORMALLY CONFIRMED ORDER & ISSUED PACKING LIST.
MANUFACTURER‑ISSUED SHIPMENT DOCUMENTS
ALL DOCUMENTS ARE OFFICIALLY ISSUED AND STAMPED BY THE ORIGINAL FIBER MANUFACTURER. DISTRIBUTOR OR TRADER‑GENERATED COPIES ARE NOT ACCEPTED.
- ORIGINAL MANUFACTURER DATASHEET
- BATCH‑CORRESPONDING COA / FACTORY TEST CERTIFICATE
- ITU‑T STANDARD CONFORMANCE STATEMENT / CERTIFICATE
SUPPLY & PACKING
WE OFFER RELIABLE LARGE‑VOLUME SUPPORT FOR GLOBAL INDUSTRIAL BUYERS.
- MONTHLY SUPPLY CAPACITY: 200,000 KM ~ 1,000,000 KM
- CO‑OPERATION OPTION: 2‑YEAR LONG‑TERM FRAMEWORK SUPPLY CONTRACT
- EXPORT PACKING: MARINE‑GRADE WOODEN / PLASTIC SPOOLS FOR SEA FREIGHT
TYPICAL APPLICATIONS
- TETHERED‑DRONE FPV OPTICAL DATA‑LINK SYSTEM
- FTTH / FTTX ACCESS NETWORK PROJECTS
- METRO & LONG‑HAUL TELECOMMUNICATION NETWORKS
- LARGE‑VOLUME INDUSTRIAL B2B EXPORT PROJECTS
- LONG‑TERM FRAMEWORK‑BASED BULK PROCUREMENT
GET SAMPLES & COMMERCIAL QUOTATION
CONTACT US TO OBTAIN PRODUCT SAMPLES, FULL TECHNICAL DOCUMENT SET AND FORMAL COMMERCIAL OFFER.
SEND INQUIRY